Cable Unipolar Wire FLRY-B ISO 6722 Class B Sec. 1,50 mmq Light Blue
ErreBi code: 48792
Price for meter
Read moreShow lessPrice for meter
€0.43
(tax excl.)
€0.52
(tax incl.)
Condition
New
Reference:
RBCVFLRYB1.5AZ
Brand:
Add to wishlist(2)
APPLICATIONS
PVC insulated flexible single core cables that is intended for use on low voltage electrical installations, systems and components of road vehicles where the heat exposure is not continuous on cable surface The FR125 F5 cables are mainly intended for the wiring everywhere a frequent thermal loading, but continuously on cable, could be occurred.
CABLE STRUCTURE
1. Flexible electrolytic bare copper conductor: stranded multi-wire
2. Type B and class T2 105°C rated PVC insulation
Temperature range: -40 to 105°C (fixed)
Short-circuit temperature: 160°C
Voltage: 220 V. c.a. 300 V. c.c.
Test voltage: 3 kV AC (<= 0.50 mmq), 5 kV AC (> 0.50 mmq)
Flame resistance: DIN 72551 Part 5, 7.Z8220, Par. 3.7
Bending radius: >= 6 x D (fixed)
Suitable for indoor use
Suitable for fixed installation
Resistance to chemical agents: DIN 72551 Part 5, ISO 6722, 7.Z8220 Par. 3.8
Resistance to diesel and gasoline: ISO 6722, 7.Z8220 Par. 3.8
Resistance to engine oil: ISO 6722 (ISO 1817 oil No. 3), 7.Z8220, Par. 3.8 (Class O1 oil)
Read moreShow less
PVC insulated flexible single core cables that is intended for use on low voltage electrical installations, systems and components of road vehicles where the heat exposure is not continuous on cable surface The FR125 F5 cables are mainly intended for the wiring everywhere a frequent thermal loading, but continuously on cable, could be occurred.
CABLE STRUCTURE
1. Flexible electrolytic bare copper conductor: stranded multi-wire
2. Type B and class T2 105°C rated PVC insulation
Temperature range: -40 to 105°C (fixed)
Short-circuit temperature: 160°C
Voltage: 220 V. c.a. 300 V. c.c.
Test voltage: 3 kV AC (<= 0.50 mmq), 5 kV AC (> 0.50 mmq)
Flame resistance: DIN 72551 Part 5, 7.Z8220, Par. 3.7
Bending radius: >= 6 x D (fixed)
Suitable for indoor use
Suitable for fixed installation
Resistance to chemical agents: DIN 72551 Part 5, ISO 6722, 7.Z8220 Par. 3.8
Resistance to diesel and gasoline: ISO 6722, 7.Z8220 Par. 3.8
Resistance to engine oil: ISO 6722 (ISO 1817 oil No. 3), 7.Z8220, Par. 3.8 (Class O1 oil)
RBCVFLRYB1.5AZ
Data sheet
- Product type
- FLRY-B Cable
- Color
- Light Blue
- external diameter
- 2.35 mm
- Voltage
- 50V
- Operating temperature min.
- -40°C
- Operating temperature max.
- +105°C
- Insulation material
- PVC
- Conductor (Material)
- Red copper
- Cable section mmq
- 2.50 mmq
- Shielding
- No
- Voltage test
- 5000V
- Type of employment
- Automotive Sector
- Resistance of the conductor
- <= 12.7 Ohm/Km
- Minimum order quantity
- 5
- Unit Type