Cable Unipolar Wire N07V-K sec. 1,00 mmq Yellow
ErreBi code: 18324
Price for meter
Read moreShow lessPrice for meter
€0.85
(tax excl.)
€1.04
(tax incl.)
Condition
New
Reference:
RBCV1N07GL
Brand:
Add to wishlist
Nominal voltage Uo/U: 450/750 V
Minimum operating temperature: -10°C (without mechanical stress)
Maximum operating temperature: 70°C
Minimum installation temperature: 5°C
Maximum short circuit temperature: 160°C
Maximum tensile stress: 50 N/mm2
Minimum bending radius: 4 x maximum external diameter
Use and installation
For systems requiring not propagating fire cables. For installation in surface conduits or embedded conduits or similar closed systems. Suitable for fixed and protected installation in lighting appliances and switching and control equipments, allowed for voltages up to 1000 V a.c. or up to 750 V d.c. to ground. The 1 mm² section is provided (in addition to others) only for internal wiring in switchboards for signalling and control or for electric circuits of lifts and hoists. For fire risk installations, the maximum temperature must not exceed 55°C. (ref. CEI 20-40)
Read moreShow less
Minimum operating temperature: -10°C (without mechanical stress)
Maximum operating temperature: 70°C
Minimum installation temperature: 5°C
Maximum short circuit temperature: 160°C
Maximum tensile stress: 50 N/mm2
Minimum bending radius: 4 x maximum external diameter
Use and installation
For systems requiring not propagating fire cables. For installation in surface conduits or embedded conduits or similar closed systems. Suitable for fixed and protected installation in lighting appliances and switching and control equipments, allowed for voltages up to 1000 V a.c. or up to 750 V d.c. to ground. The 1 mm² section is provided (in addition to others) only for internal wiring in switchboards for signalling and control or for electric circuits of lifts and hoists. For fire risk installations, the maximum temperature must not exceed 55°C. (ref. CEI 20-40)
RBCV1N07GL
Data sheet
- Product type
- Cable H07V-K
- Color
- Yellow
- external diameter
- 2.50 mm
- Voltage
- 750V
- Operating temperature min.
- -10°C
- Operating temperature max.
- +70°C
- Insulation material
- PVC
- Conductor (Material)
- Electrolytic Copper
- Cable section mmq
- 1.00 mmq
- Number of strands
- 32
- Size of the strands
- 0.193 mm
- Shielding
- No
- Voltage test
- 2500V
- Flame resistance
- CEI EN 60332-1-2
- Type of employment
- Internal Wiring
- Resistance of the conductor
- <= 19.5 Ohm/Km
- Minimum order quantity
- 5
- Unit Type
- metres