APPLICATIONS
PVC insulated flexible single core cables that is intended for use on low voltage electrical installations, systems and components of road vehicles where the heat exposure is not continuous on cable surface The FR125 F5 cables are mainly intended for the wiring everywhere a frequent thermal loading, but continuously on cable, could be occurred.
CABLE STRUCTURE
1. Flexible electrolytic bare copper conductor: stranded multi-wire
2. Type B and class T2 105°C rated PVC insulation
Temperature range: -40 to 105°C (fixed)
Short-circuit temperature: 160°C
Rated voltage: 220 V. c.a. 300 V. c.c.
Test voltage: 3 kV AC (<= 0.50 mmq), 5 kV AC (> 0.50 mmq)
Flame resistance: DIN 72551 Part 5, 7.Z8220, Par. 3.7
Bending radius: >= 6 x D (fixed)
Suitable for indoor use
Suitable for fixed installation
Resistance to chemical agents: DIN 72551 Part 5, ISO 6722, 7.Z8220 Par. 3.8
Resistance to diesel and gasoline: ISO 6722, 7.Z8220 Par. 3.8
Resistance to engine oil: ISO 6722 (ISO 1817 oil No. 3), 7.Z8220, Par. 3.8 (Class O1 oil)
Lee masShow less
PVC insulated flexible single core cables that is intended for use on low voltage electrical installations, systems and components of road vehicles where the heat exposure is not continuous on cable surface The FR125 F5 cables are mainly intended for the wiring everywhere a frequent thermal loading, but continuously on cable, could be occurred.
CABLE STRUCTURE
1. Flexible electrolytic bare copper conductor: stranded multi-wire
2. Type B and class T2 105°C rated PVC insulation
Temperature range: -40 to 105°C (fixed)
Short-circuit temperature: 160°C
Rated voltage: 220 V. c.a. 300 V. c.c.
Test voltage: 3 kV AC (<= 0.50 mmq), 5 kV AC (> 0.50 mmq)
Flame resistance: DIN 72551 Part 5, 7.Z8220, Par. 3.7
Bending radius: >= 6 x D (fixed)
Suitable for indoor use
Suitable for fixed installation
Resistance to chemical agents: DIN 72551 Part 5, ISO 6722, 7.Z8220 Par. 3.8
Resistance to diesel and gasoline: ISO 6722, 7.Z8220 Par. 3.8
Resistance to engine oil: ISO 6722 (ISO 1817 oil No. 3), 7.Z8220, Par. 3.8 (Class O1 oil)
RBCVFLRYB0.5NR
Ficha técnica
- Tipo de producto
- Cable FLRY-B
- Color
- Negro
- Diámetro externo
- 1.50 mm
- Voltaje
- 50V
- Temperatura de funcionamiento min.
- -40°C
- Temperatura de funcionamiento maxn.
- +105°C
- Material de aislamiento
- PVC
- Conductor (Material)
- Cobre rojo
- Cable de sección mmq
- 0.50 mmq
- Número de hebras
- 16
- Blindaje
- No
- Prueba de voltaje
- 3000V
- Tipo de empleo
- Sector Automotriz
- Resistencia del conductor
- <= 37.1 Ohm/Km
- Minima pedido
- 5
- Tipo de unidad
- metros